你知道構建空氣凈化工程重要的要求有哪些嗎?
- 發(fā)布人:
- 發(fā)布日期:2017-04-14 09:46:48
外凈化原理
External cleaning principle
氣流→初效空氣處理→空調→中效空氣處理→風機送風→凈化管道→高效送風口→潔凈室→帶走塵土(細菌)→回風夾道→新風、初效空氣處理。
Airflow, early efficiency air handling, air conditioning, air treatment, fan air supply, purification pipeline, efficient delivery outlet, clean room, take the dust (bacteria) - > return lined, fresh air, at the beginning of the efficiency of air processing.
重復以上進程,即可到達凈化意圖。
Repeat the process, you can reach the purpose of purification.
技術參數
technical parameter
換氣次數:十萬級10-15次/小時;萬級15-25次/小時;千級50-52次/小時;百級操作臺斷面風速0.25-0.35m/s。
Air change times: 10 one hundred thousand - 15 times / hour; 10 thousand 15 - 25 times / hour; 1000 class 52 - 50 times / hour.
壓差:主車間對相鄰房間≥5Pa。
The pressure difference of the adjacent room: the main workshop is more than 5Pa.
溫度:冬天>16℃±2℃;夏日 <26℃±2℃;
Temperature: Winter > 16 degrees C + 2 C; summer < 26 C + 2 c;
相對濕度:45-65%(RH);噪聲≤65dB(A);新風補充量:總送風量的20%-30%;
Relative humidity: 45 - 65% (RH) = 65dB (A); noise; air supply: the total air flow rate of 20% - 30%;
照度:≥300Lux。
Illumination: more than 300Lux.
空氣凈化工程構造材料
Air purification engineering construction material
1.干凈室墻、頂板資料普通采用50mm厚的夾芯彩鋼板、凈化專用的氧化鋁型材制造。門采用凈化密閉門,窗采用鋁合金玻璃固定窗。
1 clean room wall, roof material common use of 50mm thick sandwich color steel plate, purification special aluminum oxide production. Door used to clean the closed door, the window of aluminum alloy glass fixed window.
2.空中采用環(huán)氧自流平或高級耐磨塑料干凈地板。
2 air with epoxy self leveling or advanced wear-resistant plastic clean floor.
3.凈化通風管道選用鍍鋅薄鋼板制造,并采用“PEF”阻燃型的保溫板做保溫。
3 purification ventilation pipe selection of galvanized sheet steel manufacturing, and the use of "PEF" flame retardant insulation board to do heat preservation.
- 上一篇:潔凈室人員退出時應注意的事項
- 下一篇:潔凈廠房設計施工:潔凈室自凈時間檢測