不銹鋼過濾器運用前有必要檢查配件和密封圈是不是完全,有無損壞,然后按請求把它裝好。
Before the stainless steel filter is used, it is necessary to check the fittings and sealing ring for damage or damage, and then install it as requested.
新的過濾器有必要用清潔劑清潔潔凈(請不要用酸類清潔)洗凈后用高溫蒸汽滅菌、消毒、洗凈的濾器要放好,避免污染。
The new filter is necessary to clean and clean with detergent (please don't clean with acids), wash it with high temperature steam, sterilize and clean the filter, and avoid pollution.
在過濾器的裝置時進出口不要接反,管道濾器底板邊上的口是液體進口處,管道接在濾芯插口的管子是潔凈液體出口處。
When the filter is installed, the inlet and the outlet are not connected, and the mouth of the bottom of the pipe filter is a liquid inlet, and the pipe connected to the filter core socket is the outlet of the clean liquid.
新的濾芯是出產廠家在潔凈的出產廠房內用塑料袋封裝的未運用切勿撕破塑料包裝,運用請求較高的濾芯,裝置好后要通過高溫蒸汽滅菌消毒。
The new filter core is produced by a manufacturer in a clean factory building and is packed in a plastic bag. If it is not used, do not tear the plastic packing. Use a higher filter. The equipment should be sterilized by high temperature steam.
濾芯插進口時,濾芯必定要筆直,插進口后壓板扣住頂級翅片,扭緊螺絲不動即可。226接口的濾芯進口后,應旋轉90度卡緊,這是裝置中的要害,如果有一點不小心,就會達不到密封,簡單漏水,就達不到運用請求。
Import filter inserted, filter must be inserted after the buckle plate imported straight top fin, twist screw fixed. 226 interface filter element imports, should rotate 90 degrees tight, this is the key in the device, if there is a little careless, it will not reach the seal, simple water leakage, can not reach the application request.
筒體的壓力表是液體壓力顯現表,如果是二級過濾,榜首過濾器壓力表指數稍少一些是正常景象,運用時刻越長,壓力會增大,流速削減,這說明濾芯空地大多已被阻塞,要沖刷或許更換新的過濾芯。
The cylinder pressure gauge is liquid pressure meter, if it is the top two filters, filter pressure gauge index slightly less is the normal phenomenon, with longer time, the pressure will increase, flow rate cuts, which shows that most of them have been blocking filter space, perhaps to scour and replace the filter element new.
在過濾時,運用的壓力通常在0.1MPa左右,能滿意出產需求就能夠了,跟著時刻與流量添加,濾芯微孔阻塞,壓力添加,通常不要超越0.4MPa,最高肯定不能超越0.6MPa。否則會損壞濾器濾芯或被擊穿,在運用精細過濾器時格外應當留意。
When filtering, the use of pressure is about 0.1MPa, can meet the production needs to follow the flow, time and add filter pores blocking, adding pressure, usually do not exceed 0.4MPa, the highest is certainly not beyond 0.6MPa. Otherwise it will damage the filter element or be broken down, and should pay attention to the use of fine filter.
反沖刷濾芯,必定要用無菌水,否則會污染濾芯。反沖辦法,原出口變進口,把無菌水反方向打進去(要留意封閉原液過濾管道),翻開排污口,操作人員看到濾液明顯好轉為宜。
Recoil filter element, must use sterile water, otherwise it will pollute the filter. Recoil method, the original export to import, the sterile water in the opposite direction to play (pay attention to close the original filter pipe), turn on the sewage outfall, the operator saw a clear improvement of filtrate is appropriate.
產完成不必時,盡量把濾液放光,停機時刻不長,通常不要翻開機器,濾芯不要拔掉,停機時刻長或許濾液不宜過夜寄存,停機必定要清潔濾芯和濾器(也能夠用反沖辦法) 。
Do not have to complete production, try to filtrate light, stop time is not long, usually do not open the machine, don't pull down a long time filter, may not overnight stop filtrate storage, must clean filter and filter (can also be used to recoil).
自選配套運用,要留意需求的流量、壓力、泵的揚程要匹配,選型通常選用漩渦泵、輸液泵等為宜,離心泵不適用。
Optional matching, attention should be paid to the flow of demand, pressure, pump head to match, selection is usually used whirlpool pump, infusion pump is appropriate, centrifugal pump does not apply.
過濾設備的保養辦法
Maintenance of filtration equipment
長期不必,有必要把濾器清潔潔凈、濾芯拔下,洗凈烘干,用塑料袋封口寄存不要污染,濾器擦凈寄存,不要損壞。
For a long time, it is necessary to clean the filter, filter the core, wash it, dry it, seal it with plastic bag, keep it clean, clean the filter and keep it clean. Don't damage it.
換下來的濾芯要浸泡在酸堿洗液里,浸泡時刻不要超越24小時,酸堿液溫度通常在25℃—50℃。主張酸或堿與水比時10-20%為好。蛋白質含量較高的濾液、濾芯最好用酶溶液浸泡,清潔作用好,更新再運用,必定要清潔潔凈再用蒸汽消毒,清潔消毒對水過濾器和枯燥過濾器很主要。
Change the filter to be soaked in acid and alkali lotion, soaking time should not exceed 24 hours, the pH temperature usually at 25 - 50 degrees. 10-20% is better than acid or base when compared with water. The filtrate and filter high protein content of the best enzyme solution soak, cleaning effect is good, then use the update, must be clean and steam disinfection, cleaning and disinfection are mainly on the water filter and dry filter.
濾芯消毒要留意把握時刻和溫度,聚丙烯在高溫度消毒柜里以121℃為宜,用蒸汽消毒在0.1MPa蒸汽壓力下,以130℃/20分鐘為宜,聚砜和聚四氟乙烯用蒸汽消毒,能夠到達142℃、壓力0.2MPa,時刻30分鐘左右為宜,如果溫度過高,時刻過長,壓力過大,會損壞濾芯。
Filter disinfection should pay attention to grasp the time and temperature of polypropylene in high temperature disinfection cabinet to 121 degrees is appropriate, steam sterilized in 0.1MPa steam under pressure at 130 C for /20 minutes is appropriate, polysulfone and PTFE with steam sterilization, can reach 142 DEG C and the pressure of 0.2MPa, when Zhong Zuoyou 30 is appropriate, if the temperature too much time is too long, the pressure is too large, will damage the filter.